Small Size Laboratory Centrifugal Spray Dryer Machine
Model No.: TENLIN-3L ,
Inlet Temperature Control: 30~300℃
Spray Head Rotating
Speed: 36000 (R/min) Adjustable
Feeding Method: Peristaltic Pump Adjustment
-
Centrifugal Spray Dryer Stainless Steel Dryer
- Centrifugal spray dryer
-
Mold Incubator Laboratory Incubator
Purpose and Applications
- Microorganism cultivation: Provides the ideal stable conditions for growing molds, fungi, and yeasts for research, quality control, and testing.
- BOD testing: Performs Biochemical Oxygen Demand tests on water samples by maintaining a constant, low-temperature environment for microbial activity.
- Pharmaceutical and food safety: Used in drug research and for testing the safety and quality of food products.
- Other applications: Suitable for environmental protection, agricultural, and aquaculture research.
-
Precision Temperature Calibaration Baths Liquid Circulating Bath
1. Model: DC-0506. Vertical laboratory refrigerated thermostatic heating cooling circulating water bath. 2. Premium Material: The stainless steel work surface of the lab cooler is widened and thickened, and the whole machine adopts electrostatic spraying technology to prevent rust. Stainless steel cover and hidden handle design make it more convenient. 3. High Quality Circulating Pump: The cooling chiller circulation system consists of internal and external circulation. The circulating pump a... -
Thermostatic Calibration Bath Liquid Circulating Bath -30~100℃
GDH Series, Laboratory Refrigerated/heating thermostatic circulating water bath.
GDH-3006
Temperature range: -30~100℃, Tank volume: 6L.
GDH-3010
Temperature range: -30~100℃, Tank volume: 10L.
GDH-3015
Temperature range: -30~100℃, Tank volume: 15L.
GDH-3020
Temperature range: -30~100℃, Tank volume: 20L.
GDH-3030
Temperature range: -30~100℃, Tank volume: 30L.
-
Cryostat Circulator Low Temperature Circulating Glass Reactor Temperature Control System
Tenlin Instrument Co., Ltd can provide you with glass reactor system solutions, which including 20L/30L/50L/100L single glass reactor or double glass reactor together with the sealed temperature control circulating machine. We can customize based on your detailed requirements, please let us know details about your projects. We will design proper solutions for you. The glass reactor can be made into the function of explosion proof. If you have drawings or ideas, also welcome to share with us.
-
Chilling Circulator Low Temperature Benchtop Water Bath 6L 10L 15L 20L
Model: DCW series–Bench top laboratory refrigerated thermostatic heating cooling circulating water bath.
Key Specifications:
Temperature resolution: 0.01℃. Temperature Fluctuation: ± 0.05 °C. Material: 304 stainless steel.DCW-0506 Specifications:
Temperature range: -5 to +100℃, 6L. Pump flow: 6 L/min.2. Premium Material: The stainless steel work surface of the lab cooler is widened and thickened, and the whole machine adopts electrostatic spraying technology to prevent rust. Stainless steel cover and hidden handle design make it more convenient.
3. High Quality Circulating Pump: The cooling chiller circulation system consists of internal and external circulation. The circulating pump adds a cooling fan, which is more durable and prolongs the service life.
4. INTELLIGENT CONTROL: Intelligent instrument control, easy to operate, can correct the deviation of the temperature measurement value, high-temperature control accuracy, and good stability.
5. PROTECTION SYSTEM: The refrigeration has overheating and over current protection. The control system has over-temperature tweet alarms, which can set the upper and lower limits of the temperature. The over-temperature alarm temperature can automatically cut off the load when over-temperature.
6. Heat Emission Hole: The Low-temperature chillers are designed with multiple vent holes for rapid heat dissipation and stable temperature.
7. Draining Valve: The refrigerated water chiller adopts an Invisible drain valve design, clean appearance, more convenient drain.
8. WIDE APPLICATION: Recirculating water cooling Chiller is particularly suitable for chemical, biological, and physical laboratory work under normal conditions or where low temperatures are required.
-
Ultra Low Temperature Cryogenic Circulator Water Bath for Temperature Control System
Laboratory Refrigerated Thermostatic Water Bath are widely used in biology, chemical engineering, chemistry, pharmaceuticals, life sciences, and physical property testing. Provide users with a controlled cold and hot field source with uniform and constant temperature. Conduct constant temperature experiments or tests on experimental samples or produced products, and can also serve as a heat or cold source for direct heating or cooling and auxiliary heating or cooling. ● The latest sel... -
Magnetic Stirring Rod Circulation Bath Refrigeration Circulator Benchtop-5~100C 6L 10L 15L 30L
The DCW-L series constant temperature magnetic stirring reaction bath has a built-in magnetic stirring device, which can maintain the sample temperature uniformly for a long time and the stirring speed is infinitely adjustable from 0 to 1500 rpm.
I. Refrigeration System:
Employs a low-noise, air-cooled, fully enclosed compressor unit, ensuring rapid cooling and strong temperature stability.
II. Control System:
Utilizes self-developed temperature control technology, equipped with a PT100 compressor and fully imported electronic components.
III. Circulation System:
Composed of an internal circulation system, ensuring highly uniform and stable liquid temperature within the tank.
IV. Protection System:
Features overheat and overcurrent protection, an over-temperature alarm, and automatic load cut-off in case of over-temperature conditions. Optional: Liquid level protection.
V. Large-Screen LCD Control Instrument:
PID control can be automatically searched or manually adjusted. Optional: 485 communication protocol.
VI. Main Applications and Scope of Application:
Suitable for various departments in metrology, biochemistry, petroleum, meteorology, energy, environmental protection, and pharmaceutical industries.
-
Benchtop Low Temperature Refrigeration Circulator Water Bath -5~100C 6L 10L 15L 20L 100L
Model: DCW series–Bench top laboratory refrigerated thermostatic heating cooling circulating water bath.
Temperature resolution: 0.01℃. Temperature Fluctuation: ± 0.05 °C. Material: 304 stainless steel.
DCW-0506, Temperature range: -5 to +100℃, 6L. Pump flow: 6 L/min.
DCW-0508, Temperature range: -5 to +100℃, 8L. Pump flow: 6 L/min.
DCW-0510, Temperature range: -5 to +100℃, 10L. Pump flow: 6 L/min.
DCW-0515, Temperature range: -5 to +100℃, 15L. Pump flow: 6 L/min.
DCW-0520, Temperature range: -5 to +100℃, 20L. Pump flow: 6 L/min.
DCW-0530, Temperature range: -5 to +100℃, 30L. Pump flow: 13L/min.
-
Low Temperature Circulator High Digital Resolution High Accuracy 0.01C
● Large screen LCD display, temperature display resolution up to 0.01℃.
● With over-temperature protection, over-temperature alarm, over-temperature alarm temperature can be set, and the load can be cut off automatically when the temperature is over.
● Timing function, the total working time of the equipment can be set and the load can be cut off automatically when the time comes.
● Hidden cooling coil design ensures larger space for use in the tank.
● Intelligent software with strong temperature stability, PID can automatically adjust the best parameters according to different media, and special users can also manually readjust the parameters.
● Digital locking of the control system with the software can avoid wrong operation by unrelated personnel and ensure the correct data of the experiment process.
● High efficiency totally enclosed compressor refrigeration, fast cooling speed, with multiple protection such as overheating and over-current.
● Standard equipped with international needs of users in multiple scenes.
-
Cryostat Circulator Ultra Low Temperature Control Circulating Bath-80~100C
Short Description:
- Refrigerated Heating Lab Circulating Water Bath
- Temperature range: -50℃ ~ 100℃, Tank Volume: 6~30L
- Temperature Resolution: 0.01℃, Temperature Fluctuation: ±0.05℃
- Model: DC-5006~DC-5030:-50~100℃, 6~30L
- Model: DC-6006~DC-6030:-60~100℃, 6~30L
- Model: DC-7006~DC-7030:-70~100℃, 6~30L
- Model: DC-8006~DC-8030:-80~100℃, 6~30L